Logo-ajdr
Submitted: 16 Apr 2022
Accepted: 06 Feb 2024
ePublished: 29 Mar 2024
EndNote EndNote

(Enw Format - Win & Mac)

BibTeX BibTeX

(Bib Format - Win & Mac)

Bookends Bookends

(Ris Format - Mac only)

EasyBib EasyBib

(Ris Format - Win & Mac)

Medlars Medlars

(Txt Format - Win & Mac)

Mendeley Web Mendeley Web
Mendeley Mendeley

(Ris Format - Win & Mac)

Papers Papers

(Ris Format - Win & Mac)

ProCite ProCite

(Ris Format - Win & Mac)

Reference Manager Reference Manager

(Ris Format - Win only)

Refworks Refworks

(Refworks Format - Win & Mac)

Zotero Zotero

(Ris Format - Firefox Plugin)

Avicenna J Dent Res. 2024;16(1): 16-21.
doi: 10.34172/ajdr.1645
  Abstract View: 29
  PDF Download: 18

Original Article

Effects of Combinations of Hydrogen Peroxide and Vinegar in Different Ratios on the Surface Roughness of Heat-Cure Denture Base Acrylic Resin

Farnaz Firouz 1,2 ORCID logo, Saeed Nikanjam 2* ORCID logo, Armaghan Shahbazi 1 ORCID logo, Zahra Cheraghi 3 ORCID logo, Abdollah Nazari doost 4 ORCID logo

1 Dental Implants Research Center, Hamadan University of Medical Sciences, Hamadan, Iran
2 Department of Prosthodontics, Faculty of Dentistry, Hamadan University of Medical Sciences, Hamadan, Iran
3 Department of Biostatistics, Faculty of Health, Hamadan University of Medical Sciences, Hamadan, Iran
4 Undergraduate Student, Faculty of Dentistry, Hamadan University of Medical Sciences, Hamadan, Iran
*Corresponding Author: Saeed Nikanjam, Email: saeed.nikanjam@umsha.ac.ir

Abstract

Background: Complete dentures are at high risk of contamination, and their disinfection is imperative to prevent cross-contamination. Also, chemical disinfecting agents can effectively eliminate microorganisms. This study aimed to assess the effect of combinations of hydrogen peroxide (HP) and vinegar in different ratios on the surface roughness of heat-cure denture base acrylic resin.

Methods: This in vitro, experimental study evaluated 40 heat-cure acrylic resin specimens that were flasked and heated at 70 ° C for 9 hours for heat polymerization. The acrylic specimens were cut into small cubic pieces measuring 20×20×3 mm using a cutting machine and polished with metallographic abrasive paper. The specimens were randomized into 4 groups of control (artificial saliva) and HP and vinegar in 1:1, 1:3, and 3:1 ratios (three experimental groups). Then, they were immersed in the respective solutions for 8 hours/day for one month. Their surface roughness (Ra) was measured before and after immersion by a profilometer. The data were analyzed using a one-way analysis of variance (α=0.05).

Results: The immersion of acrylic specimens in HP+vinegar in 1:1 and 1:3 ratios did not cause a significant change in their surface roughness (P>0.05). However, the surface roughness significantly decreased after immersion in HP+vinegar in a 3:1 ratio (P=0.032). Despite the reduction in the surface roughness of specimens in the 3:1 group, the difference in surface roughness was not significant among the four groups after immersion (P>0.05).

Conclusion: Combinations of HP and vinegar in different ratios appear to be suitable for cleaning removable dentures due to their insignificant effects on the surface roughness of acrylic resin.


Please cite this article as follows: Firouz F, Nikanjam S, Shahbazi A, Cheraghi Z, Nazari doost A. Effects of combinations of hydrogen peroxide and vinegar in different ratios on the surface roughness of heat-cure denture base acrylic resin. Avicenna J Dent Res. 2024; 16(1):16-21. doi:10.34172/ajdr.1645
First Name
Last Name
Email Address
Comments
Security code


Abstract View: 30

Your browser does not support the canvas element.


PDF Download: 18

Your browser does not support the canvas element.