Logo-ajdr
Submitted: 18 Feb 2021
Accepted: 06 Mar 2021
ePublished: 29 Jun 2021
EndNote EndNote

(Enw Format - Win & Mac)

BibTeX BibTeX

(Bib Format - Win & Mac)

Bookends Bookends

(Ris Format - Mac only)

EasyBib EasyBib

(Ris Format - Win & Mac)

Medlars Medlars

(Txt Format - Win & Mac)

Mendeley Web Mendeley Web
Mendeley Mendeley

(Ris Format - Win & Mac)

Papers Papers

(Ris Format - Win & Mac)

ProCite ProCite

(Ris Format - Win & Mac)

Reference Manager Reference Manager

(Ris Format - Win only)

Refworks Refworks

(Refworks Format - Win & Mac)

Zotero Zotero

(Ris Format - Firefox Plugin)

Avicenna J Dent Res. 2021;13(2): 47-51.
doi: 10.34172/ajdr.2021.09
  Abstract View: 706
  PDF Download: 528

Original Article

The Effect of Glaze Coating on Wear Resistance of Some Acrylic Denture Teeth: An In Vitro Study

Samaneh Abbasi 1, Soodabe Ebrahimi 2* ORCID logo, Arash Shisheian 1, Maryam Farhadian 3

1 Assistant Professor, Department of Prosthodontics, School of Dentistry, Hamadan University of Medical Sciences, Hamadan, Iran.
2 Postgraduate student of prosthodontics, Department of Prosthodontics, School of Dentistry, Hamadan University of Medical Sciences, Hamadan, Iran.
3 Associate Professor, Department of Biostatistics, School of public Health Hamadan University of Medical Sciences, Hamadan, Iran.
*Corresponding Author: Correspondence to Soodabe Ebrahimi Tel: +989182439979, Fax: +98811-8381085, Email: , Email: dr.s.ebrahimi94@gmail.com

Abstract

Background: Acrylic resin teeth wear resistance has an important role in the denture longevity. This study aimed to clarify the effect of glaze coating on wear resistance of three types of artificial acrylic teeth.

Methods: In this in vitro study, the wear resistance rate of three of acrylic denture teeth (GENIUS, STON and CLASSIC) was compared with Ivoclar teeth (n=25/group). The wear resistance was measured by estimating the weight loss in pre and post removing glaze coating, following 5000 cycles in the chewing simulator device. Data analysis was made using paired t test, one-way ANOVA and Tukey’s post hoc test.

Results: ANOVA test showed that there was no significant difference between the mean amount of wear of GENIUS, CLASSIC, STON and IVOCLAR teeth in the first stage (P <0.061), but this difference was significant (P <0.001) in the second stage. The result of Tukey post hoc test showed that wear rates of GENIUS were significantly lower than other groups (P<0.001). Comparison between the mean wear rates of each dental group at the first and second stages showed a significant difference between average teeth wear resistance of CLASSIC, STON and IVOCLAR in the first and second stages (P <0.001).

Conclusions: In conclusion, the teeth wear resistance of STON and CLASSIC were similar to IVOCLAR. Also, after removing the glaze coating, the teeth wear resistance decreased in all groups but was not statistically significant for group GENIUS.



Citation: Abbasi S, Ebrahimi S, Shisheian A, Farhadian M. The effect of glaze coating on wear resistance of some acrylic denture teeth: an in vitro study. Avicenna J Dent Res. 2021;13(2):47-51. doi: 10.34172/ajdr.2021.09.
First Name
Last Name
Email Address
Comments
Security code


Abstract View: 707

Your browser does not support the canvas element.


PDF Download: 528

Your browser does not support the canvas element.