﻿<?xml version="1.0" encoding="UTF-8"?>
<ArticleSet>
  <Article>
    <Journal>
      <PublisherName>Hamadan University of Medical Sciences</PublisherName>
      <JournalTitle>Avicenna Journal of Dental Research</JournalTitle>
      <Issn>2423-7582</Issn>
      <Volume>14</Volume>
      <Issue>1</Issue>
      <PubDate PubStatus="ppublish">
        <Year>2022</Year>
        <Month>03</Month>
        <DAY>29</DAY>
      </PubDate>
    </Journal>
    <ArticleTitle>A Hollow Complete Denture Fabricated Using Neutral Zone Approach for a Severely Resorbed Ridge: A Case Report</ArticleTitle>
    <FirstPage>47</FirstPage>
    <LastPage>52</LastPage>
    <ELocationID EIdType="doi">10.34172/ajdr.2022.09</ELocationID>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName>Romal</FirstName>
        <LastName>Shende</LastName>
        <Identifier Source="ORCID">https://orcid.org/0000-0002-2213-5438</Identifier>
      </Author>
      <Author>
        <FirstName>Suryakant</FirstName>
        <LastName>Deogade</LastName>
      </Author>
      <Author>
        <FirstName>Arun</FirstName>
        <LastName>Khalikar</LastName>
      </Author>
      <Author>
        <FirstName>Sattyam</FirstName>
        <LastName>Wankhade</LastName>
      </Author>
      <Author>
        <FirstName>Pronoy</FirstName>
        <LastName>Mukhopadhyay</LastName>
      </Author>
    </AuthorList>
    <PublicationType>Journal Article</PublicationType>
    <ArticleIdList>
      <ArticleId IdType="doi">10.34172/ajdr.2022.09</ArticleId>
    </ArticleIdList>
    <History>
      <PubDate PubStatus="received">
        <Year>2021</Year>
        <Month>10</Month>
        <Day>14</Day>
      </PubDate>
      <PubDate PubStatus="accepted">
        <Year>2021</Year>
        <Month>11</Month>
        <Day>29</Day>
      </PubDate>
    </History>
    <Abstract>Prosthetic rehabilitation using complete dentures is quite a challenging task when accompanied by severely atrophic ridges. Various modifications are required in the treatment strategy to optimize the prognosis of the finished prosthesis. Moreover, the increased inter-arch space demands the hollowing of the maxillary denture to mitigate the issues in retention due to increased weight. This case report aims to demonstrate a technique used to fabricate a hollow maxillary denture and a mandibular denture using the neutral zone approach in the case of a severely atrophied ridge.</Abstract>
    <ObjectList>
      <Object Type="keyword">
        <Param Name="value">Neutral zone</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Hollow denture</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Atrophic ridge</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">All green technique</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Increased inter-ridge distance</Param>
      </Object>
    </ObjectList>
  </Article>
</ArticleSet>